Home
Diesel Tank
Cryogenic Tank
LPG Tank
LPG Skid Plant
Accessories
Contact
(English)
Home
Diesel Tank
Cryogenic Tank
LPG Tank
LPG Skid Plant
Accessories
Contact
Select Language
English
Arabic
Bulgarian
Chinese (Simplified)
Chinese (Traditional)
Croatian
Czech
Danish
Dutch
Finnish
French
German
Greek
Hindi
Italian
Japanese
Korean
Norwegian
Polish
Portuguese
Romanian
Russian
Spanish
Swedish
Catalan
Filipino
Hebrew
Indonesian
Latvian
Lithuanian
Serbian
Slovak
Slovenian
Ukrainian
Vietnamese
Albanian
Estonian
Galician
Hungarian
Maltese
Thai
Turkish
Persian
Afrikaans
Malay
Swahili
Irish
Welsh
Belarusian
Icelandic
Macedonian
Yiddish
Armenian
Azerbaijani
Basque
Georgian
Haitian Creole
Urdu
Bengali
Bosnian
Cebuano
Esperanto
Gujarati
Hausa
Hmong
Igbo
Javanese
Kannada
Khmer
Lao
Latin
Maori
Marathi
Mongolian
Nepali
Punjabi
Somali
Tamil
Telugu
Yoruba
Zulu
Myanmar (Burmese)
Chichewa
Kazakh
Malagasy
Malayalam
Sinhala
Sesotho
Sudanese
Tajik
Uzbek
Amharic
Corsican
Hawaiian
Kurdish (Kurmanji)
Kyrgyz
Luxembourgish
Pashto
Samoan
Scottish Gaelic
Shona
Sindhi
Frisian
Xhosa
Cryogenic Tank
carbon dioxide storage tank
liquid nitrogen tank
(9) After the low-temperature valve is used for a period of time, liquid leakage will occur. If slight leakage is found in the upper gland, the packing gland should be tightened. If the valve core ...
Keep the site tidy around LNG storage tanks
(8) The valve connected to the storage tank shall not be used as a control valve for incoming and outgoing materials, and frequent switching is not allowed. It should be kept in a normally open sta...
The valve connecting the LNG storage tank to the storage tank is opened and closed regularly
(7) There are pressure gauges and differential pressure level gauges on the storage tanks, as well as on-site instructions and remote transmission. The remote transmission is used to collect automa...
LNG storage tanks have pressure gauges and differential pressure level gauges
(5) The outer surface of the storage tank should be inspected regularly for deformation, corrosion, frosting, condensation and other abnormal phenomena, and any problems should be reported and deal...
The outer surface of LNG storage tanks should be inspected regularly
(3) The foundation of the storage tank should be regularly observed to see if there is any subsidence or damage. Problems found should be reported and dealt with in a timely manner. (4...
The foundation of LNG storage tanks should be observed frequently
Low temperature storage tank: (1) Determination of vacuum degree between inner and outer interlayers (one-year cycle) (2) Routinely check the supporting facilities of ...
LNG gasification station equipment maintenance
(3) Check the pipe shrinkage and pipe support support changes; (4) Check the tightness of the cryogenic valve; (5) Bring the storage tank to working condition and test the...
Design and installation of standard station for cryogenic LNG storage tanks
Inspect and test the low-temperature performance of cryogenic equipment and pipelines for pre-cooling purposes, including: (1) Check whether the quality of low-temperature materials is...
LNG gasification station pre-cooling technology
Among them, the mixed-flow type has the advantages of both forward and counter-flow arrangements and avoids its disadvantages, that is, high utilization of the heating surface, good heat transfer e...
The ideal and common layout of cryogenic storage tanks
This type of low-temperature storage tank usually does not have a drum. The heating surface is composed of multiple sets of tube rows and headers. It has a compact structure, is easy to manufacture...
The cryogenic storage tank has a compact structure and is easy to manufacture and install.
Secondly, according to the hot water circulation method, it can be divided into two categories: forced circulation hot water low-temperature storage tanks and natural circulation hot water low-temp...
Forced circulation cryogenic storage tank
Simply speaking, cryogenic storage tanks can be divided into three simple categories. First of all, according to the temperature of the working medium in the pot, it can be divided into two categor...
Cryogenic storage tanks can be divided into three simple categories
Because after the steam low-temperature storage tank is used for a period of time, scale will definitely appear. If scaling occurs, it will definitely affect the warming effect of the wall of the s...
There are many types of cryogenic storage tanks used
After the hydraulic pressure experiment is completed. Adjust the hot water low-temperature storage tank to a full state, and then open the hot water low-temperature storage tank until steam appears...
Hydraulic pressure test of cryogenic storage tanks
Generally, pressure gauges, liquid level gauges, safety valves, bursting disc devices, etc. should be calibrated or replaced at least once a year. If any malfunction is found in cryogenic liquid st...
Periodic verification of cryogenic storage tanks
Cryogenic storage tanks are special equipment subject to national compulsory safety supervision and are included in the third category of pressure vessels. They should be subject to regular ins...
Normal operation and safe use of cryogenic storage tanks
Regularly check the vacuum degree in the jacket of the cryogenic liquid storage tank. If the vacuum degree deteriorates, additional vacuuming measures should be taken (the tank vacuuming should...
Regularly check the vacuum inside the jacket of cryogenic liquid storage tanks
During the normal use of cryogenic storage tanks, there should be a dedicated person responsible for patrol inspection. Check that the pressure in the inner container must not exceed the workin...
Normal use process of cryogenic storage tanks
Before a cryogenic liquid storage tank is put into use, it should be ensured that the container is in good sealing condition, that various accessories (including valves, instruments, and safety dev...
Precautions before using cryogenic liquid storage tanks
When using cryogenic storage tanks, the "Safety Rules for the Use of Cryogenic Liquid Storage and Transportation Equipment" (JB6898-1997) should be strictly implemented and daily safety managem...
Daily safety management should be strengthened when using cryogenic storage tanks
Operators must pass the training and assessment of the quality and technical supervision department at the municipal level or above and hold a pressure vessel operation qualification certificate be...
Safety protection of cryogenic storage tank equipment
Workers who operate cryogenic storage tanks should have a detailed understanding of the structural characteristics of the equipment and its pipe and valve systems, be familiar with the dangerou...
Structural characteristics of cryogenic storage tank equipment and its pipe and valve system
The main function of cryogenic storage tanks is to fill and store cryogenic liquids. For cryogenic liquid storage The safe use requirements of tanks should comprehensively consider the...
Important points for safe use of cryogenic storage tanks
This is the coating used in low-temperature storage tanks. If anti-corrosion is not done well, it will directly affect the use and service life of the storage tank. The choice of anti-corrosion coa...
Use and service life of cryogenic storage tanks
The outer surface of the low-temperature storage tank bottom plate is made of water-based lithium silicate zinc-rich coating. It has good anti-corrosion effect, will not affect the welding construc...
The outer surface of the cryogenic storage tank bottom plate is made of water-based lithium silicate zinc-rich coating
Apply two coats, with a thickness >80μm; use the matching intermediate paint of GR heat-insulating reflective paint as the intermediate paint, and apply two coats, with a thickness >100μm; us...
Total dry film thickness of composite coating for cryogenic storage tanks
The outer surface of the low-temperature storage tank uses GR heat-insulating reflective paint, which is weather-resistant and stain-resistant. It plays a role in insulating and cooling against hig...
The outer surface of the cryogenic storage tank uses GR heat insulation reflective coating
With the development of technology, light-colored non-carbon electrostatic conductive anti-corrosion coatings are now available. Applying 4 coats of non-carbon electrostatic conductive anti-corrosi...
Total coating dry film thickness for cryogenic storage tanks
Normally, the inner surface of the low-temperature storage tank is made of carbon-based electrostatically conductive paint, which is prone to pitting, which will affect its service life.
The service life of cryogenic storage tanks
The low-temperature storage tank has anti-corrosion properties because it is coated with anti-corrosion coatings on both the inner and outer surfaces of the low-temperature storage tank, and differ...
Cryogenic storage tanks have anti-corrosion properties