The main problem is: ①The diameter of the hole exceeds half of the cylinder: a cylinder with a diameter of ?1800 and a hole diameter of ?1200. According to the regulations of GB150: the diameter of...
Rated 4.6/5 based on 589 customer reviews
Share:
Content

The main problem is: ①The diameter of the hole exceeds half of the cylinder: a cylinder with a diameter of ?1800 and a hole diameter of ?1200. According to the regulations of GB150: the diameter of the opening should not exceed 1000mm, and its technical requirements: manufactured and inspected according to GB150 are not in compliance with the regulations.